Whether you’re spraying foam or applying polyurea coatings, Graco Reactor Plural-Component Systems help you get the job done with superior results. Available in air, electric or hydraulic technology – we have the right equipment to meet your needs.
Description
| MODEL | Hydraulic (H Series) | ||
| Reactor 2 H-30 | Reactor 2 H-40 | Reactor 2 H-50 | |
| Max Working Pressure | 2000 psi (138 bar, 13.8 MPa) |
2000 psi (138 bar, 13.8 MPa) |
2000 psi (138 bar, 13.8 MPa) |
| Min Working Pressure | 700 psi (48 bar, 4.8 MPa) | 600 psi (41 bar, 4.1 MPa) | 600 psi (41 bar, 4.1 MPa) |
| Max Hose Length | 310 ft (94 m) | 410 ft (125 m) | 410 ft (125 m) |
| Max Fluid Temp | 190˚F (88˚C) | 190˚F (88˚C) | 190˚F (88˚C) |
| Output | 28 lb (12.3 kg)/min | 45 lb (20 kg)/min | 52 lb (23.6 kg)/min |
| Weight | 10 kW: 530 lb (240 kg) 15 kW: 556 lb (252 kg) | 600 lb (272 kg) | 600 lb (272 kg) |
| Reactor App Compatible | Yes | Yes | Yes |
| Ordering Information | With 10.2 kW heater: 17H131 – Elite 17H031 – standard With 15.3 kW heater: 17H132 – Elite 17H032 – standard *Amps 10kW: 230V, 1-ph — 79A 230V, 3-ph — 46A 400V, 3-ph — 35A 15kW: 230V, 1-ph — 100A 230V, 3-ph — 59A 400V, 3-ph — 35A |
With 15.3 kW heater: 230V, 3-ph — 71A 17H143 – Elite 17H043 – standard 400V, 3-ph — 41A 17H145 – Elite 17H045 – standard With 20.4 kW heater: 230V, 3-ph — 95A 17H144 – Elite 17H044 – standard 400V, 3-ph — 52A 17H146 – Elite 17H046 – standard |
With 20.4 kW heater: 230V, 3-ph — 95A 17H153 – Elite 17H053 – standard 400V, 3-ph — 52A 17H156 – Elite 17H056 – standard |
| Packages | ‡ ∆ | ‡ ∆ | ‡ ∆ |
| Operation manual | 334945 | 334945 | 334945 |
| Repair manual | 334946 | 334946 | 334946 |